IBM鲨鱼存储更换硬盘

字数 1610阅读 3572评论 1赞 0
在ESS Master Console中用ESS Terminal Selector登录Service Main Menu

Main Service Menu
->repair menu
 ->show/repair problems needing repair
  ->找对对应的报错信息,并把当前光标停留在报错信息上,按下回车键
   ->仔细阅读详细报错信息,并把光标停留在需要更换FRU的那一行(该未注释掉)
    ->按照屏幕提示, make resources not available for customer use[选择该项,按Enter键]
     ->等待已坏硬盘的告警灯变黄色后,拔掉坏硬盘
      ->换上新硬盘,等待约5秒钟,新硬盘的告警灯也为黄色
       ->FRUs have been replaced [选择该项,按Enter键]
        ->verify the FRUs that were replaced [选择该项,按Enter键]
         ->屏幕显示相应的信息提示,请等待,新硬盘告警灯黄色消失
          ->屏幕显示硬盘format,initialize,certify进度和时间(约需2小时)
           ->continue the repair process[选择该项,按Enter键]
             show the result of verification operation[可以查看前面操作的结果]
            -> retain the resources for customer use [选择该项,按Enter键]
             ->屏幕提示有关硬盘的报错信息的状态已经closed,请将光标移到以下项:
               None[选择该项,按Enter键]
              ->end of repair action[选择该项,按Enter键]
               ->完成后,请检查报错和硬盘的状态是否正确,如果正确,则换盘成功