HPUX系统下EMC CX300更换HBA步骤
1, HP主机更换HBA卡,没有删除旧的链接,导致powerpath路径显示异常.
CLARiiON ID=CK200050400808
Logical device ID=6006016050E01200A429C7C82295D911
state=alive; policy=CLAROpt; priority=0; queued-IOs=0
Owner: default=SP A, current=SP A
==============================================================================
---------------- Host --------------- - Stor - -- I/O Path - -- Stats ---
==============================================================================
14 0/4/0/0.1.0.239.0.0.0 c14t0d0 SP B1 active dead 0 0
15 0/4/0/0.1.1.239.0.0.0 c15t0d0 SP A1 active dead 0 0
16 1/10/0/0.1.0.239.0.0.0 c16t0d0 SP B0 active alive 0 0
17 1/10/0/0.1.1.239.0.0.0 c17t0d0 SP A0 active alive 0 0
CLARiiON ID=CK200050400808
Logical device ID=6006016050E01200E6255D592295D911
state=alive; policy=CLAROpt; priority=0; queued-IOs=0
Owner: default=SP A, current=SP A
==============================================================================
---------------- Host --------------- - Stor - -- I/O Path - -- Stats ---
==============================================================================
14 0/4/0/0.1.0.239.0.0.1 c14t0d1 SP B1 active dead 0 0
15 0/4/0/0.1.1.239.0.0.1 c15t0d1 SP A1 active dead 0 0
16 1/10/0/0.1.0.239.0.0.1 c16t0d1 SP B0 active alive 0 0
17 1/10/0/0.1.1.239.0.0.1 c17t0d1 SP A0 active alive 0 0
CLARiiON ID=CK200050400808
Logical device ID=6006016050E01200F89F4BDF2195D911
state=alive; policy=CLAROpt; priority=0; queued-IOs=0
Owner: default=SP A, current=SP A
==============================================================================
---------------- Host --------------- - Stor - -- I/O Path - -- Stats ---
==============================================================================
14 0/4/0/0.1.0.239.0.0.2 c14t0d2 SP B1 active dead 0 0
15 0/4/0/0.1.1.239.0.0.2 c15t0d2 SP A1 active dead 0 0
16 1/10/0/0.1.0.239.0.0.2 c16t0d2 SP B0 active dead 0 2028
17 1/10/0/0.1.1.239.0.0.2 c17t0d2 SP A0 active alive 0 2055
2,使用fcmsutil命令查看HBA卡的WWN号.
Class I H/W Path Driver S/W State H/W Type Description
=================================================================
fc 0 0/4/0/0 td CLAIMED INTERFACE HP Tachyon TL/TS Fibre Char
/dev/td0
fc 1 1/10/0/0 td CLAIMED INTERFACE HP Tachyon TL/TS Fibre Char
/dev/td1
heb_set4#[/]fcmsutil /dev/td0
Vendor ID is = 0x00103c
Device ID is = 0x001028
TL Chip Revision No is = 2.3
PCI Sub-system Vendor ID is = 0x00103c
PCI Sub-system ID is = 0x000006
Topology = PTTOPT_FABRIC
Local N_Port_id is = 0x010c00
N_Port Node World Wide Name = 0x50060b00000b584f
N_Port Port World Wide Name = 0x50060b00000b584e
Driver state = ONLINE
Hardware Path is = 0/4/0/0
Number of Assisted IOs = 8696318
Number of Active Login Sessions = 2
Dino Present on Card = NO
Maximum Frame Size = 960
Driver Version = @(#) libtd.a HP Fibre Channel Tachyon4
heb_set4#[/]fcmsutil /dev/td1
Vendor ID is = 0x00103c
Device ID is = 0x001028
TL Chip Revision No is = 2.3
PCI Sub-system Vendor ID is = 0x00103c
PCI Sub-system ID is = 0x000006
Topology = PTTOPT_FABRIC
Local N_Port_id is = 0x010800
N_Port Node World Wide Name = 0x50060b00000b84db
N_Port Port World Wide Name = 0x50060b00000b84da
Driver state = ONLINE
Hardware Path is = 1/10/0/0
Number of Assisted IOs = 1542169050
Number of Active Login Sessions = 2
Dino Present on Card = NO
Maximum Frame Size = 960
Driver Version = @(#) libtd.a HP Fibre Channel Tachyon4
读出新更换 HBA 为 td0, WWN 号为: 50060b00000b584f /50060b00000b584e
3,登陆EMC Navisphere进入工程模式(同时按ctrl+shift+F12),密码:messner,添加新HBA链接;
connectivity status
检查 HBA WWN 是否在 CX300 注册激活;如果有灰色没激活,请手工加入,点击页面“ new ”按钮
手工输入 WWN ,50:06:0b:00:00:58:4f:50:06:0b:00:00:0b:58:4e
SP-PORT:A-1 (B-1)
Initiator TYPE: HP NO AUTO TRASPASS
Existinghost : heb_set4
4, WWN手工安装完成后,从新回到主菜单,点HOST键。
Reconnect , 把新加入的 HBA 与继续从新 connect 一下;
5,在HP主机上,扫描硬盘;
heb_set4#[/sbin/init.d] ioscan –fnCdisk
……..
heb_set4#[/sbin/init.d] powermt display dev=all
heb_set4#[/sbin/init.d]powermt display dev=all
CLARiiON ID=CK200050400808
Logical device ID=6006016050E01200A429C7C82295D911
state=alive; policy=CLAROpt; priority=0; queued-IOs=0
Owner: default=SP A, current=SP A
==============================================================================
---------------- Host --------------- - Stor - -- I/O Path - -- Stats ---
==============================================================================
14 0/4/0/0.1.0.239.0.0.0 c14t0d0 SP B1 active alive 0 0
15 0/4/0/0.1.1.239.0.0.0 c15t0d0 SP A1 active alive 0 0
16 1/10/0/0.1.0.239.0.0.0 c16t0d0 SP B0 active alive 0 0
17 1/10/0/0.1.1.239.0.0.0 c17t0d0 SP A0 active alive 0 0
CLARiiON ID=CK200050400808
Logical device ID=6006016050E01200E6255D592295D911
state=alive; policy=CLAROpt; priority=0; queued-IOs=0
Owner: default=SP A, current=SP A
==============================================================================
---------------- Host --------------- - Stor - -- I/O Path - -- Stats ---
==============================================================================
14 0/4/0/0.1.0.239.0.0.1 c14t0d1 SP B1 active alive 0 0
15 0/4/0/0.1.1.239.0.0.1 c15t0d1 SP A1 active alive 0 0
16 1/10/0/0.1.0.239.0.0.1 c16t0d1 SP B0 active alive 0 0
17 1/10/0/0.1.1.239.0.0.1 c17t0d1 SP A0 active alive 0 0
CLARiiON ID=CK200050400808
Logical device ID=6006016050E01200F89F4BDF2195D911
state=alive; policy=CLAROpt; priority=0; queued-IOs=0
Owner: default=SP A, current=SP A
==============================================================================
---------------- Host --------------- - Stor - -- I/O Path - -- Stats ---
==============================================================================
14 0/4/0/0.1.0.239.0.0.2 c14t0d2 SP B1 active alive 0 0
15 0/4/0/0.1.1.239.0.0.2 c15t0d2 SP A1 active alive 0 0
16 1/10/0/0.1.0.239.0.0.2 c16t0d2 SP B0 active dead 0 2028
17 1/10/0/0.1.1.239.0.0.2 c17t0d2 SP A0 active alive 0 2055
如还有 Dead 进程,执行以下命令。
heb_set4#[/sbin/init.d] powermt check
heb_set4#[/sbin/init.d] powermt config
heb_set4#[/sbin/init.d]powermt restore hba=all
heb_set4#[/sbin/init.d]powermt display dev=all
CLARiiON ID=CK200050400808
Logical device ID=6006016050E01200A429C7C82295D911
state=alive; policy=CLAROpt; priority=0; queued-IOs=0
Owner: default=SP A, current=SP A
==============================================================================
---------------- Host --------------- - Stor - -- I/O Path - -- Stats ---
==============================================================================
14 0/4/0/0.1.0.239.0.0.0 c14t0d0 SP B1 active alive 0 0
15 0/4/0/0.1.1.239.0.0.0 c15t0d0 SP A1 active alive 0 0
16 1/10/0/0.1.0.239.0.0.0 c16t0d0 SP B0 active alive 0 0
17 1/10/0/0.1.1.239.0.0.0 c17t0d0 SP A0 active alive 0 0
CLARiiON ID=CK200050400808
Logical device ID=6006016050E01200E6255D592295D911
state=alive; policy=CLAROpt; priority=0; queued-IOs=0
Owner: default=SP A, current=SP A
==============================================================================
---------------- Host --------------- - Stor - -- I/O Path - -- Stats ---
==============================================================================
14 0/4/0/0.1.0.239.0.0.1 c14t0d1 SP B1 active alive 0 0
15 0/4/0/0.1.1.239.0.0.1 c15t0d1 SP A1 active alive 0 0
16 1/10/0/0.1.0.239.0.0.1 c16t0d1 SP B0 active alive 0 0
17 1/10/0/0.1.1.239.0.0.1 c17t0d1 SP A0 active alive 0 0
CLARiiON ID=CK200050400808
Logical device ID=6006016050E01200F89F4BDF2195D911
state=alive; policy=CLAROpt; priority=0; queued-IOs=1
Owner: default=SP A, current=SP A
==============================================================================
---------------- Host --------------- - Stor - -- I/O Path - -- Stats ---
==============================================================================
14 0/4/0/0.1.0.239.0.0.2 c14t0d2 SP B1 active alive 0 0
15 0/4/0/0.1.1.239.0.0.2 c15t0d2 SP A1 active alive 1 0
16 1/10/0/0.1.0.239.0.0.2 c16t0d2 SP B0 active alive 0 0
17 1/10/0/0.1.1.239.0.0.2 c17t0d2 SP A0 active alive 0 0
检查完毕,EMC CX300加入HBA成功。
如果觉得我的文章对您有用,请点赞。您的支持将鼓励我继续创作!
赞2
添加新评论0 条评论