Power 750的重量、长宽高、耗电量:
解答:宽度(Width):440 mm (17.3 in)
深度(Depth): 730 mm (28.7 in)
高度(Height): 173 mm (6.81 in)
重量(Weight): 48.7 kg (107.4 lb)
最大耗电量:1950 watts
最大散热量:6,655 Btu/hour
2012-05-07
页数3
浏览5191
下载8

已下载用户的评价7.09分

您还未下载该资料,不能发表评价;
查看我的 待评价资源
TerryZ05TerryZ05项目经理DC2012-05-14
没用
整理得真详细 以前倒是没怎么注意这些参数
yukay2010yukay2010系统工程师神州数码系统集成服务有限公司2012-05-07
没用
收藏了。。。。
zp_ccczp_ccc高级技术主管国内某金融科技公司2012-05-07
没用
IBM POWER 520 SERVER Physical Specifications Deskside/Desktop: Width: 328.5 mm (12.9 in) with tip foot 182.3 mm (7.2 in) without tip foot Depth: 628 mm (24.7 in) Height: 540 mm (21.3 in) Rack-Mount: Width: 440 mm (17.3 in) Depth: 538 mm (21.2 in) Height: 173 mm (6.8 in) Weight (with tip foot): Rack-mount: 31.75 kg (70 lb) Deskside: 40.8 kg (90 lb) Operating Environment Temperature: Non-Operating: 5 to 43 degrees C (41 to 109 F) Operating: 5 to 35 degrees C (41 to 95 F) Relative humidity: 8% to 80% Maximum dew point: 27 degrees C (80.6 F)(nonoperating) 17 degrees C (62.6 F) (operating) Operating voltage: 100 to 127 or 200 to 240 V ac at 50 to 60 plus or minus 0.5 Hz (auto-ranging) Operating frequency: 50/60 Hz Power consumption: 850 watts (maximum) Power factor: 0.97 Thermal output: 2,901 Btu/hour (maximum) Power-source loading: 0.876 kva (maximum configuration) Maximum altitude: 3,048 m (10,000 ft) Noise level and sound power Deskside system: 6.4 bels idle / 6.5 bels operating Rack-mount drawer: 6.8 bels idle / 6.8 bels operating EMC conformance classification This equipment is subject to FCC rules and shall comply with the appropriate FCC rules before final delivery to the buyer or centers of distribution. U.S.: FCC Class A Europe: CISPR 22 Class A Japan: VCCI-A Korea: Korean Requirement Class A China: People's Republic of China commodity inspection law Class A
zp_ccczp_ccc高级技术主管国内某金融科技公司2012-05-07
没用
IBM POWER 550 SERVER Physical Specifications Deskside/Desktop: Width: 282.5 mm (12.1 in) with tip foot 182.5 mm (7.2 in) without tip foot Depth: 778 mm (30.6 in) Height: 540 mm (21.3 in) Weight: 57.2 kg (126.1 lb) with tip foot 53.7 kg (117.3 lb) without tip foot Rack-Mount: Width: 440 mm (17.3 in) Depth: 730 mm (28.7 in) Height: 173 mm (6.81 in) Weight: 48.7 kg (107.4 lb) Operating Environment Temperature: (nonoperating) 5 to 40 degrees C (41 to 104 F); recommended temperature (operating) 5 to 35 degrees C (41 to 95 F) Relative humidity: 8% to 80% Maximum dew point: 17 degrees C (62.6 F)(operating) 27 degrees C (80.6 F)(nonoperating) Operating voltage: 100 to 127 (2- or 4-core system) or 200 to 240 (6-core or 8- core system) V ac at 50 to 60 plus or minus 0.5 Hz (auto-ranging). Operating frequency: 50/60 Hz Power consumption: 1500 watts (maximum) Power factor: 0.97 Thermal output: 4,778 Btu/hour (maximum) Power-source loading 1.443 kVa (maximum configuration) Maximum altitude: 3,048 m (10,000 ft) Noise level and sound power Deskside system: 7.0 bels idle/7.0 bels operating Rack-mount drawer: 7.0 bels idle/7.0 bels operating EMC Conformance Classification This equipment is subject to FCC rules and shall comply with the appropriate FCC rules before final delivery to the buyer or centers of distribution. U.S.: FCC Class A Europe: CISPR 22 Class A Japan: VCCI-A Korea: Korean Requirement Class A China: People's Republic of China commodity inspection law Class A Homologation -- Telecom Environmental Testing (Safety and EMC) Homologation approval for specific countries has been initiated with the IBM Homologation and Type Approval (HT&A) organization in LaGaude, France. This System p model and applicable features meet the environmental testing requirements of the country telecom and have been designed and tested in compliance with the Full Quality Assurance Approval (FQAA) process as delivered by the British Approval Board for Telecom (BABT), the U.K. Telecom regulatory authority. Product safety/country testing/certification UL 60950 Underwriters Laboratory, Safety Information CSA C22.2 No. 60950-00, Canadian Standards Association EN60950 European Norm IEC 60950, Edition 1, International Electrotechnical Commission, Safety Information GS Mark (Safety, TUV, EN60950)-Germany, Europe Nordic deviations to IEC 60950-1 1st Edition General requirements The product is in compliance with IBM Corporate Bulletin C-B 0-2594-000 Statement of Conformity of IBM Product to External Standard (Suppliers Declaration). Systems Product category: F Power consumption in active mode: 1100 watts (maximum) Base processor configuration Composite Theoretical Performance (CTP): 87,500 MTOPS (2-core 3.5 GHz) 153,125 MTOPS (4-core 3.5 GHz) 271,250 MTOPS (8-core 3.5 GHz) 105,000 MTOPS (2-core 4.2 GHz) 183,750 MTOPS (4-core 4.2 GHz) 325,500 MTOPS (8-core 4.2 GHz) Note: MTOPS = Millions of theoretical operations per second. Measurements made with four processors, maximum memory, and one disk drive unit. Note: CTP numbers are determined for the base configuration and cannot automatically be used for export license determination.
szhangkangszhangkang项目经理aaa2012-05-07
没用
狼哥整理的很全面
zp_ccczp_ccc高级技术主管国内某金融科技公司2012-05-07
没用
IBM POWER 570 SERVER Physical Specifications IBM Power 570 model MMA CEC enclosure: Width: 483 mm (19.0 in.) Depth: 824 mm (32.4 in.) from front of Bezel to rear of Power Supply 674 mm (25.6 in.) front rack rail mounting surface to I/O Adapter Bulkhead 793 mm (31.2 in.) front rack rail mounting surface to rear of Power Supply Height: 174 mm (6.85 in) 4 EIA units Weight: 63.6 kg (140 lb) Dimensions and specifications shown are for a single drawer. Model MMA systems can have one to four CEC enclosures. To help assure installability and serviceability in non-IBM, industry- standard racks, review the vendor's installation planning information for any product-specific installation requirements. Operating Environment Temperature: 5 to 45 degrees C (41 to 113 F) nonoperating 5 to 35 degrees C (41 to 95 F) operating Relative humidity: (noncondensing) 8% to 80% operating 5% to 100% nonoperating Maximum wet bulb: 27 degrees C (80 F) nonoperating 23 degrees C (73 F) operating Operating voltage: 200 to 240 V ac Operating frequency: 50/60 Hz Power consumption: 1400 watts maximum (per enclosure with all (four or eight) cores active) Power source loading: 1.428 kVA maximum (per enclosure with all (four or eight) cores active) Thermal output: 4778 BTU/hr maximum (per enclosure with all (four or eight) cores active) Noise level: (one CEC enclosure with two processor features and all cores active, operating and idle) Processor With With Feature # Frequency Standard Door Acoustic Door --------- --------- ------------- ------------- 5620 3.5 GHz 7.4 bels 6.9 bels 5622 4.2 GHz 7.4 bels 6.9 bels 7380 4.7 GHz 7.7 bels 7.2 bels 7387 4.4 GHz 7.4 bels 6.9 bels 7388 5.0 GHz 7.7 bels 7.2 bels 7540 4.2 GHz 8.0 bels 7.5 bels The standard and acoustic doors are front door features on the rack. The 7014-T00, T42 and B42 racks offer both Standard and Acoustic front door features as options to accommodate a Clients choice for their environment. For additional Noise level references see the 9117-MMA Site and Hardware Planning Guide. Maximum altitude: 3,048 m (10,000 ft) For system configurations with processor feature #7540 installing above 2400 meters, additional ambient room temperature limits are in effect. Please refer to the Site and Hardware Planning Guide for details. EMC Conformance Classification This equipment is subject to FCC rules and shall comply with the appropriate FCC rules before final delivery to the buyer or centers of distribution. U.S.: FCC CFR47 Part 15 Class A Europe: CISPR 22 Class A; "CE" Mark of Conformity Japan: VCCI-A Korea: Korean Requirement Class A China: People's Republic of China commodity inspection law Taiwan: BSMI CNS 13438 (Taiwan EMC Standard) AustraliaNew Zealand: ACA C-Tick Homologation Telecom Environmental Testing (Safety and EMC) Homologation approval for specific countries has been initiated with the IBM Homologation and Type Approval (HT&A) organization in LaGaude, France. This System p model and applicable features meet the environmental testing requirements of the country telecom and have been designed and tested in compliance with the Full Quality Assurance Approval(FQAA) process as delivered by the British Approval Board for Telecom (BABT), the U.K. telecom regulatory authority. Product Safety/Country testing/certification UL 60950-1 1st Edition Underwriters Laboratory, Safety Information CAN/CSA22.2 No. 60950-1 1st Edition EN60950-1:2001 European Norm GS Mark (Safety, TUV, EN60950)-Germany, Europe IEC 60950-1 1st Edition, International Electrotechnical Commission, Safety Information Nordic deviations to IEC 60950-1 1st Edition General requirements The product is in compliance with IBM Corporate Bulletin C-B 0-2594-000 Statement of Conformity of IBM Product to External Standard (Suppliers Declaration). Systems Product category (2007): C Power consumption in active mode: 779 watts ( maximum for #5620, 2 Core 3.5 GHz processor) Power consumption in energy savings mode: 683 watts ( maximum for #5620, 2-Core 3.5 GHz processor) Base processor configuration Composite Theoretical Performance (CTP): 87,500 MTOPS (for #5620, 2-Core 3.5 GHz processor)
zp_ccczp_ccc高级技术主管国内某金融科技公司2012-05-07
没用
IBM POWER 595 SERVER Physical Specifications Width: 74.9 cm (29.5 in) rack only 77.5 cm (30.5 in) rack with side door 77.5 cm (30.5 in) rack with slimline or acoustic door and side doors, one frame 156.7 cm (61.7 in) rack with slimline or acoustic door and side doors, two frames 77.5 cm (30.5 in) rack with slimline front door and rear door heat exchange (RDHX), CEC frame only Depth: 127.3 cm (50.1 in) rack only 148.6 cm (58.5 in) rack with slimline and side doors, one or two frames 180.6 cm (71.1 in) rack with acoustic and side doors, one or two frames 152.1 cm (61.3 in) rack with slimline front door and RDHX, CEC frame only Height: 201.4 cm (79.3 in) Weight: The maximum stand-alone weight of a fully populated Power 595 CEC rack with eight processor books and without covers: 1,451 kg (3,200 lb)three I/O drawers and without IBB 1,542 kg (3,400 lb)two I/O drawers and with IBB The maximum stand-alone weight of a powered Expansion Rack without covers: 1,361 kg (3,000 lb) eight I/O drawers and without IBB 1,452 kg (3,200 lb) seven I/O drawers and with IBB The maximum stand-alone weight of a powered Expansion Rack and a bolt-on Expansion Rack without covers: 2,518 kg (5,550 lb)16 I/O drawers and without IBB 2,609 kg (5,750 lb)15 I/O drawers and with IBB Door kits (front and rear): 65.5 kg (145 lbs) Rear door heat exchanger with acoustical front door and acoustical insert 50.8 (112 lbs) Rear door heat exchanger and slimline front door 30 kg (66 lbs) Slimline covers, front and rear doors 50.8 kg (112 lbs) Acoustic doors for expansion frame (front and rear) 41.7 kg (92 lbs) Acoustic door for CEC frame, front and rear 25.2 kg (55 lbs) Rack side cover panels, pair (Need to add to the system weight of 3200 lbs) To assure installability and serviceability in non-IBM industry- standard racks, review the installation planning information for any product-specific installation requirements. Operating Environment Temperature: For 16-to 32-core systems: 10 to 32 degrees C# (50 to 90 degrees F), degraded linearly down to 24 degrees C (75 degrees F) from 1,295 to 3,048 m (4,250 to 10,000 ft) For 48-to 64-core systems: 10 to 28 degrees C# (50 to 82 degrees F), degraded linearly down to 24 degrees C (75 degrees F) from 1,295 to 2,133 m (4,250 to 7,000 ft) Note: # The above maximum temperatures of 32 degrees C (90 degrees F) and 28 degrees C (82 degrees F) are linearly derated above 1,295 m (4,250 ft). Relative humidity: 20% to 80% Maximum wet bulb: 23 degrees C (73 F) (operating) Sound power: Declared A-weighted sound power level, per ISO 9296: 9.2 bels (with slimline doors) Declared A-weighted sound power level, per ISO 9296: 8.2 bels (with acoustical doors) Sound pressure: Declared A-weighted one-meter sound pressure level, per ISO 9296: 79 decibels (with slimline doors) Declared A-weighted one-meter sound pressure level, per ISO 9296: 69 decibels (with acoustical doors) Note: Noise levels are given for the principal (typical) configuration of the CEC rack. The 10-dB reduction in noise levels with the acoustical doors corresponds to a factor of 10 reduction. That is, the noise level from a single rack with slimline doors would be about the same as the noise level from 10 racks with acoustical doors, combined. Power requirements Operating voltages (3-phase V ac at 50/60 Hz): 200 to 240 V; 380 to 415 V; 480 V Rated current (A per phase): 48 A or 63 A or 80 A; 34 A or 43 A; 24 A or 34 A Inrush current: TBD A (maximum) Power consumption: 27,500 watts (maximum for full CEC, three I/O drawers) Power source loading: 27.7 kVA Thermal output: 27,500 joules/sec (93,840 Btu/hr) maximum The CEC Bulk Power Assembly (BPA) is served by dual line cords. The following line cords are required: For 4.2 GHz processors with six or more processor books (one of these): 80 A breaker rating for USA, Canada, Japan 200 - 240 V with 100 A plug, 6 AWG 30 A breaker rating with 30 A plug and USA High Voltage Service (480 V), 8 AWG 80 A breaker rating with no plug and World Trade Low Voltage (200 - 240 V), 6 AWG 40 A breaker rating with no plug and World Trade High Voltage Service (380 - 415 V), 8 AWG For 5.0 GHz processors with five or more processor books (one of these): 80 A breaker rating for USA, Canada, Japan 200 - 240 V with 100 A plug, 4 AWG 60 A breaker rating with 60 A plug and USA High Voltage Service (480 V), 6 AWG 100 A breaker rating with no plug and World Trade Low Voltage (200 - 240 V), 4 AWG 63 A breaker rating with no plug and World Trade High Voltage Service (380 - 415 V), 6 AWG For CEC frames with fewer than the above processor books, the following line cords may also be used (one of these): 60 A breaker rating for USA, Canada, Japan 200 - 240 V with 60 A plug, 6 AWG 30 A breaker rating with 30 A plug and USA High Voltage Service (480 V), 8 AWG 60 A breaker rating with no plug and World Trade Low Voltage (200 - 240 V), 6 AWG 40 A breaker rating with no plug and World Trade High Voltage Service (380 - 415 V), 8 AWG The I/O Expansion Frame with Bulk Power Assembly (BPA) is served by dual line cords. The following line cords are required for expansion frames servicing eight or more I/O drawers (one of these): 80 A breaker rating for USA, Canada, Japan 200 - 240 V with 100 A plug 30 A breaker rating with 30 A plug and USA High Voltage Service (480 V) 80 A breaker rating with no plug and World Trade Low Voltage (200 - 240 V) 40 A breaker rating with no plug and World Trade High Voltage Service ( 380-415 V) For powered I/O Expansion Frames servicing fewer than eight I/O drawers, the following line cords may also be used (one of these): 60 A breaker rating for USA, Canada, Japan 200 - 240 V with 60 A plug 30 A breaker rating with 30 A plug and USA High Voltage Service ( 480 V) 80 A breaker rating with no plug and World Trade Low Voltage (200 - 240 V) 40 A breaker rating with no plug and World Trade High Voltage Service (380 - 415 V) Systems This product meets the requirements for computer energy consumption efficiency as defined by the Energy Saving Law - Japan. Product Category (2005 law): C Product Category (2007 law): B Computer Energy Consumption Efficiency - 2005 law (Watts/MTOPS): 0.0977 (for 16-core, Standard system configuration) Computer Energy Consumption Efficiency - 2007 law (Watts/MTOPS): 0.0977 (for 16-core, Standard system configuration) EMC conformance classification This equipment is subject to FCC rules and shall comply with the appropriate FCC rules before final delivery to the buyer or centers of distribution. U.S.: FCC CFR47 Part 15 Class A Europe: CISPR 22 Class A; "CE" Mark of Conformity Japan: VCCI-1 Korea: Korean Requirement Class A Homologation - Telecom environmental testing (Safety and EMC) Homologation approval for specific countries has been initiated with the IBM Homologation and Type Approval (H&TA) organization in LaGaude, France. The Power 595 Server (9119-FHA) and applicable features meet the environmental testing requirements of the country telecom and have been designed and tested in compliance with the Full Quality Assurance Approval (FQAA) process as delivered by the British Approval Board for Telecom (BABT), the U.K. telecom regulatory authority. Product safety/Country testing/Certification U.S.: UL Canada: CNL (CSA or cUL) Germany/Europe: GS Mark (Safety, TUV, EN60 950) General requirements The Power 595 Server (9119-FHA) is in compliance with IBM Corporate Bulletin C-B 0-2594-000 Statement of Conformity of IBM Product to External Standard (Suppliers Declaration). Limitations Configuration Information Power 595 (9119-FHA) consists of the following major components: A 42U-tall, 24-inch system rack that houses the central electronics complex (CEC), Bulk Power Assembly ( BPA), and I/O drawers. A redundant power subsystem housed in the BPA's top 8U of the system rack, with optional battery backup capability (#6200). A 20U-tall CEC housing the system backplane cooling fans and system electronic components. One to eight 8-core, POWER6 processor books mounted in the CEC. Each processor book incorporates 32 memory DIMM slots and 4 GX I/O buss adapters (#1814 & #1816). The CEC supports either 4.2GHz (#4694) or 5.0GHz processor books (#4695 or #4705). Two 24" Powered Expansion Racks (#6954), each with 32U worth of rack space for up to 8x 4U I/O drawers. Each Powered Expansion Rack supports a 42U bolt-on, non-powered expansion rack for mounting additional I/O drawers supported by the 595 I/O expansion rules. One to two 24" non-powered expansion racks (#6953), each supporting up to eight I/O drawers, 4Us high. One to 30 24", 4U 12X I/O drawers (#5797) , each containing 20 PCI-X adapter slots and 16 hot-swap SCSI-3 disk bays. The adapter slots support the AIX, IBM i and Linux operating systems. The SCSI-3 disk bays are not supported by IBM i. One to 32 24", 4U 12X I/O drawers, each containing 20 PCIe adapter slots (#5803 & #5873) and 26 hot-swap SFF SAS disk bays (#5803). PCIe adapters and SAS drives are supported by AIX, IBM i and Linux operating systems. Multiple (no maximum) 19", 2.0 meter racks (0553), supporting both 2U and 4U I/O drawers. Each rack supports up to nine power distribution units (PDU), four mounted vertically and five mounted horizontally. Each PDU mounted horizontally takes up 1U of rack space. Each rack contains 40Us of mounting space. One to 185 19", 2U SAS drawers (#9477). Each drawer provides 12 hot- swap SAS bays and 11 slot filler panels. One to 110 19", 4U SCSI drawers (#5786). Each 4U drawer provides 24 Ultra 320, SCSI disk bays. IBM i only. One to 96 4U PCI-X expansion drawers (#5790). Each drawer provides 6 PCI-X slots for blind swap I/O adapters. Two drawers can be mounted side-by-side in 4U of space in a 19" rack using a Dual I/O Unit Enclosure (#7307 or #7311). IBM i only. Central electronics complex The 595 CEC is a 20U tall, 24-inch rack-mounted device. It houses the system processors, memory, redundant system service processors, I/O drawer connection capability, and associated components. It is installed immediately below the power subsystem. The 595 can be populated with up to eight POWER6 8-core processor books. Each processor book contains four MCMs. Each MCM contains memory chips with 32 MBs of L3 cache and one dual-core POWER6 processor chip with two 4 MB, integrated L2 caches and integrated memory controllers. Each dual-core processor is supported by 4 MB of private Level 2 cache and 32 MB of shared Level 3 cache. Processor books are available in 4.2 GHz and 5.0 GHz. All processor books in a 595 must operate at the same speed. Each processor book provides 32 memory card slots and 4 slots for RIO-2 or 12X dual loop adapters for attachment of I/O drawers.
黑色代码黑色代码2012-05-07
没用
这个主题还有意思,占位支持!
zp_ccczp_ccc高级技术主管国内某金融科技公司2012-05-07
没用
IBM POWER 710 SERVER Physical Specifications Rack-Mount: Width: 440 mm (19.0 in) Depth: 706 mm (27.8 in) Height: 89 mm ( 3.5 in) Weight (Maximum configuration): Power 710 -- 28.2 kg (62 lbs) Power 730 -- 29.5 kg (65 lbs) Operating Environment Temperature: (nonoperating) 5 to 45 degrees C (41 to 113 F); recommended temperature (operating) 18 to 27 degrees C (64 to 80 F); allowable operating temperature 5 to 35 degrees C (41 to 95 F) Relative humidity: Nonoperating 8% to 80%; recommended 5.5 degrees C (42 F) dew point to 60% RH and 15 degrees C (59 F) dew point Maximum dew point: 28 degrees C (84 F)(operating) Operating voltage: 100 to 127 or 200 to 240 V ac (Power 710); 200 to 240 V ac (Power 730); Operating frequency: 47/63 Hz Maximum measured power consumption: Power 710 -- 650 watts (maximum) Power 730 -- 1100 watts (maximum) Power factor: 0.98 Thermal output: Power 710 -- 2,218 Btu/hour (maximum) Power 730 -- 3,754 Btu/hour (maximum) Power-source loading Power 710 -- 0.663 kVa (maximum configuration) Power 730 -- 1.122 kVa (maximum configuration) Maximum altitude: 3,050 m (10,000 ft) Note: The maximum measured value is the worst case power consumption expected from a fully populated server under an intensive workload. The maximum measured value also accounts for component tolerance and non-ideal operating conditions. Power consumption and heat load vary greatly by server configuration and utilization. The IBM Systems Energy Estimator should be used to obtain a heat output estimate based on a specific configuration: [url]http://www-912.ibm.com/see/EnergyEstimator[/url] Noise level and sound power (Preliminary data) Power 710: 6.6 bels (Operating and idling) Power 730: 6.6 bels (Operating and idling)
zp_ccczp_ccc高级技术主管国内某金融科技公司2012-05-07
没用
IBM POWER 720 SERVER: Physical Specifications Rack-mount: Width: 440 mm (17.3 in) Depth: 610 mm (24.0 in) Height: 173 mm (6.81 in) Weight: 48.7 kg (107.4 lb) Tower: Width without tip plate: 183 mm (7.2 in) Width with tip plate: 328.5 mm (12.9 in) Depth : 688 mm (27.1 in) Height: 541 mm (21.3 in) Weight without tip plate: 53.7 kg (118.1 lb) Weight with tip plate: 57.2 kg (125.8 lb) Operating Environment Operating environment system exception with the 1.5 TB/3.0 TB LTO-5 SAS Tape Drive (#5638). Temperature (operating) 10 to 25 degrees C (50 to 95 F); allowable operating temperature 10 to 40 degrees C (50 to 104 F) Relative humidity: Nonoperating 10% to 80% noncondensing Maximum altitude: 3,048 m (10,000 ft) System environment limits without the 1.5 TB/3.0 TB LTO-5 SAS Tape Drive (#5638). Temperature: (nonoperating) 5 to 45 degrees C (41 to 113 F); recommended temperature (operating) 18 to 27 degrees C (64 to 80 F); allowable operating temperature 5 to 35 degrees C (41 to 95 F) = Relative humidity: Nonoperating 8% to 80%; recommended 5.5 degrees C (42 F) dew point to 60% RH and 15 degrees C (59 F) dew point Maximum dew point: 28 degrees C (84 F)(operating) Operating voltage: 100 to 127 or 200 to 240 V ac Operating frequency: 47/63 Hz Maximum measured power consumption: 840 watts (maximum) Power factor: 0.98 Thermal output: 3,024,845 joules/hour (2,867 Btu/hour) (maximum) Power-source loading 0.857 kVa (maximum configuration) Maximum altitude: 3,050 m (10,000 ft) Note: The maximum measured value is the worst case power consumption expected from a fully populated server under an intensive workload. The maximum measured value also accounts for component tolerance and non- ideal operating conditions. Power consumption and heat load vary greatly by server configuration and utilization. The IBM Systems Energy Estimator should be used to obtain a heat output estimate based on a specific configuration