nkj827
作者nkj827·2020-04-04 09:41
项目经理·长春长信华天

PowerVC简要配置手册

字数 4376阅读 1581评论 0赞 19

HMC: 9.123.xx.xx labuser/passw0rd (1 P720 is being managed 。 PowerVC 不支持 Power5 ,必须是 Power6 以上。 HMC Model CR5 or later , HMC 版本最低要求是 7.7.8.0)

V7000: 9.123.xx.xx labuser/passw0rd

SAN Switch: 9.123.xx.xx labuser/passw0rd (如果需要测试 PowerVC Standard Edition , SAN Switch 需要是 Brocade 16Gb 、 Firmware 6.4 或以上,除了 SAN24B-5 和 SAN48B-5 , IBM Flex System FC5022 16 GB Scalable Switch 也是 Brocade 16Gb 的)

pLinux LPAR for PowerVC installation: 9.123.xx.xx root/passw0rd

Software Package is under /tmp/software

OS Image Template : SN06B7F5T with LPAR Name: template

如果要测试 Shared Storage Pool , HMC 需要 v8.8.1.0 或以上

如果要测试 PowerKVM ,就需要 POWER8 , HMC v8.8.1.0

Installation

  1. Mount the RHEL 6.5 ISO as a repository (如果是 PowerVC 1.2.1.0 以上版本,估计还是 RHEL 6.5 经过较多的测试)

mount –o loop /dev/sr0 /mnt/cdrom

create /etc/yum.repos.d/local.repo file, including following contents

[local]

name=local

baseurl=file:///mnt/cdrom/Server

gpgcheck=0

enabled=1

CentOS 6.5 也是可行的,但是 PowerVC 的 Install 和 Update 脚本都会报错退出,需要绕过去

  1. Check on selinux, /etc/hosts

selinux: /etc/selinux/config -> selinux=disabled/permissive 修改这个 selinux 配置后需要重启操作系统?

/etc/hosts: 9.123.xx.x lab0x.cn.ibm.com lab0x

  1. Unzip the PowerVC 1.2.1.0 package, run installation scripts
  2. Unzip the PowerVC 1.2.1.2 package, run update scripts
  3. Add HMC Connection as well as the Power Host (9.123.xxx.xx labuser/passw0rd)
  4. Add Storage Connection and SAN SW into (V7000:9.123.xx.xxx labuser/passw0rd) (SW: 9.123.xx.xxx labuser/passw0rd)

Created the SAN fabric and disabled the physically disconnected Fibre Channel ports (in the "Configuration" menu).

Created the static network to be used for to-be-deployed LPARs

User Scenarios

  1. Capture Image
  2. Using the template VM
  3. Manage the existing virtual machines for “template”
  4. Start up the “template” LPAR
  5. Run AE scripts to make sure the activating engine will be available for capture
  6. Deploy Image
  7. Input name, host policy (optional), compute template, network vlan
  8. Click deploy
  9. VM operation
  10. Stop VM
  11. Start VM
  12. Advanced operation
  13. Resize when stopped
  14. Resize when running
FunctionalityDescriptionNotes
1Validate EnvironmentRun the environment validation tool to verify the resources being managed are operating properly.
2View Host / HMC DetailsNavigate to the hosts panel and drill-down on the hosts or select the HMC connections tab at the top and view the respective details.
3Deploy Virtual ApplianceSelect a pre-populated RHEL 6.4 (RHEL-64) or AIX 7.1 (AIX-71) virtual appliance to deploy within PowerVC.Static IPs that can be used for deploy: 172.26.43.25-172.26.43.126
4View Virtual Machine DetailsNavigate to the virtual machine panel and drill down on the properties of the newly created virtual machine instance.
5Create a Storage VolumeNavigate to the storage volume panel and create a new storage volume that can be attached to a running VM instance.
6Attach Storage Volume to VMNavigate to newly created storage volume and attach to VM previously created.
7Resize VMSelect the newly created VM and resize the virtual memory and CPU as desired.
8Live Migration (Partition Mobility)Select the newly created VM and select the migrate button to live migrate the VM to the other host.
9CaptureSelect the VM and capture as a new image within the repository.* For purposes of the hosted environment you can use the VM already prepared for capture (VM2Capture). For more information on the capture process please reference the PowerVC documentation.

HMC and VIOS fixes useful for PowerVC environments

ComponentBase CodeFixesRelease Date
Hardware Management Console (HMC)7.7.8MH01388 Mandatory: Required for V7.7.8Dec 6, 2013
MH01403 Recommended: Fixed an issue where, after an upgrade to V7R7.8.0, no user profile can login to the GUI and only the user id hscroot can login using ssh.Jan 21, 2014
MH01397 Recommended. All previous PowerVC-related patches for V7.7.8Mar 10, 2014
7.7.8 SP1MH01431 Mandatory: Fixed a problem with Service Pack 1 where the cumulative fixes for IBM PowerVC were not installed.May 15, 2014
8.1.0MH01421 Mandatory: Required for V8.1.0
Virtual I/O Server (VIOS)2.2.3.1 (FP27)IV52899m1a Required iFix for PowerVC and VIOS Usability SupportDec 12, 2013
IV54776m1a Required iFix for LPM and for PowerVC and VIOS Usability SupportFeb 21, 2014
IV53197m1b Required iFix for LPM and for PowerVC and VIOS Usability Support Includes IV52899, IV53197, IV53505, IV54776Mar 31, 2014
2.2.3.3 (FP27-SP3)IV56366 Required iFix for PowerVC 1.2.1June 6, 2014